| Discovery BIO
GFC New! |
| Discovery BIO GFC phases perform size exclusion
separations over a wide molecular weight range, from small biomolecules
to virus particles. By eliminating non-specific adsorption,
the unique hydrophilic surface treatment and ultra high-purity
silica combine to allow reproducibly high recovery of active
proteins. Discovery BIO GFC is available in 5 µm spherical
particles with pore sizes from 100 to 2000 Å for high
separation capacity. The narrow pore and particle size distributions
ensure high column efficiency and reproducibility. |
| |
| Discovery BIO PolyMA-SCX |
| Efficient, high-recovery polymer-based cation-exchange
columns for protein and peptide separations. |
| |
| Discovery BIO PolyMA-WAX |
| Efficient, high-recovery polymer-based anion-exchange
columns for protein and peptide separations. |
| |
| Discovery BIO Wide
Pore C5 |
Similar retention but increased stability compared
to C4 with excellent, no bleed properties for LC-MS. Used for
proteins and hydrophobic peptides.
Now in 0.18mm ID dimensions. |
| |
| Discovery BIO Wide
Pore C8 |
| Intermediate hydrophobicity between a C4/C5
and C18 makes it a great starting point for peptide method development.
Used for peptides and small proteins. |
| |
| Discovery BIO Wide
Pore C18 |
The most hydrophobic BIO Wide Pore phase. Excellent
for synthetic and natural peptides and peptide mapping.
Now in 0.18mm ID dimensions. |
|
 |
| Literature |
| |
|
 |
Technical Bulletin:
Peptide Separations on a Stable, Aqueous-Compatible C18 Column
Most C18 HPLC columns undergo phase collapse in 100% aqueous mobile
phases with concomitant loss of retention. This causes a problem
when trying to analyze very polar compounds. This Technical Bulletin
describes how Discovery BIO Wide Pore C18 columns do not undergo
phase collapse, and can be used in 100% aqueous conditions. The
implications for polar peptides and peptides mapping is described.
(52KB pdf) |
| |
|
 |
Discovery BIO Wide Pore Brochure
Click to download the 36-page Discovery BIO Wide Pore brochure (9,866
KB pdf) |
| |
|
 |
Getting Started with RP-HPLC
for Peptides
Application Note 166 (69 KB pdf) |
| |
|
 |
Increase Sensitivity and Decrease
Sample Consumption Using HPLC Microbore and Capillary Column Dimensions Application
Note 167 (53 KB pdf) |
| |
|
 |
Eliminate TFA and Improve Sensitivity
of Peptide Analyses by LC-MS
Application Note 168 ( 58 KB pdf) |
| |
|
 |
Effect of Stationary Phase
on Selectivity of Reversed-Phase HPLC Separations of Polypeptides
Application Note 169 (75 KB pdf) |
|
 |
|
Short, Fast LC-MS Columns for Discovery Phases - C8, C18, cyano and HS F5 (more information) |
 |
| Discovery C18 and C8 |
| Classic reversed-phase selectivity and retention with
exceptional peak shape for all compounds. Excellent, no-bleed properties
for LC-MS applications. |
| |
| Discovery HS C18 |
| Non-polar, reversed-phase column with excellent, no
bleed LC-MS performance |
| |
| Discovery RP-Amide C16 |
| Polar-embedded, palmitamidopropyl reversed-phase column
with unique retention and selectivity. |
| |
| Discovery HS F5 |
Pentafluorophenyl terminated reversed-phase column
with unique retention and selectivity
(e.g. basic & halogenated compounds) |
| |
| Discovery Cyano |
| Cyanopropyl reversed-phase column with lower hydrophobicity
than C18 or C8 and unique selectivity. |
| |
| Discovery HS PEG |
Polyethylene glycol reversed-phase column with unique
retention and selectivity
(e.g. phenolic compounds) |
 |
| Discovery Zr |
| For HPLC methods at pH and temperature extremes. |
| |
| Discovery Zr-PBD |
| Polybutadiene-coated zirconia particles for operation
at pH 1-13 and up to 100°C (150°C in special hardware). Similar
selectivity to C18-silica, but with pH and thermal stability. |
| |
| Discovery Zr-PS |
| Polystyrene-coated zirconia particles for operation
at pH 1-13 and up to 100°C (150°C in special hardware). |
| |
| Discovery Zr-Carbon |
| Carbon-clad zirconia for separating isomers. Operates
from pH 1-14 and up to 100°C (200°C in special hardware). |
| |
| Discovery Zr-CarbonC18 |
| C18-bonded carbon-clad zirconia combines shape selectivity
with partitioning. Operates from pH 1-14 and up to 100°C (200°C
in special hardware). |
 |
| Literature |
| |
Discovery
HPLC Columns for
Small Molecule Separations
Rediscover HPLC method development with this
76-page brochure, a practical tutorial that describes
how Discovery allows you to develop better HPLC methods and solve
common HPLC problems. Contains method development case studies, guidelines
to choosing a Discovery column based on analyte and separation problem.
Also contains information on the new Discovery Zr products. (1,1251
KB pdf) |
| |
Discovery
Zr Method Development
Bulletin 932 (48 KB pdf) |
|